Cáp mạng Nexans LANmark-6 Cat6 U/UTP 4pair LSZH (N100.604)

Cáp mạng Nexans LANmark-6 Cat6 U/UTP 4pair LSZH (N100.604) Reel 305m

Part Number: N100.604

Complies to all Category 6 cable standard
Supports Class E application
Central cross member maintains geometry and performanc
Tested up to 350MHz


LANmark-6 cable is the ultimate solution for a future proof network. It is specifically designed to support the exacting requirements for tomorrow's rotocols, yet is fully backwards compatible with today's needs. It is the ecommended cable for all forthcoming installations.
10baseT Ethernet
100baseTX Fast Ethernet
1000baseTX Gigabit Ethernet
155 MBit ATM
622 MBit ATM
1.2 Gbit ATM
Future class E application
LANmark-6 is independently verified to exceed the requirements of the ISO/IEC 11801:2002 Category 6 requirements.


Tested to 350 MHz and with guaranteed performance to 250 MHz, Nexans LANmark-6 cables provide guaranteed headroom and bandwidth ever and above the requirements of all international, european and american cable standards, including ISO/IEC 11801:2002, IEC 61156-5, EN 50173, EN 50288, TIA/EIA 568-B.2-1.


LANmark-6 is installed in exactly the same way as Category 5 cables. The C³ central cross member reduces the risk of crushing and kinking.


Nexans LANmark-6 cable is covered by the guarantee that it is Category 6 and by a parts and labour warranty as described in the Nexans Certified System Warranty.


Construction characteristics
– Type of cable: U/UTP
– Outer sheath: LSZH
– Colour: Orange
– Screen: Unshielded
Dimensional characteristics
– Diameter over insulation: 1.02 mm
– Number of pairs: 4
– Minimum outer diameter: 5.9 mm
– Maximum outer diameter: 6.3 mm
– Approximate weight: 43 kg/km
– Conductor cross-section (AWG): 23
Electrical characteristics
– Mutual capacitance: 56 nF/km
– Max. DC-resistance of the conductor at 20°C: 70 Ohm/km
– Characteristic impedance: 100 Ohm
Transmission characteristics
– Attenuation Crosstalk Ratio, 250MHz: 5.5 db/100m
– Skew: 30 ns/100m
– Coupling attenuation at 30 MHz: 45 db
– Velocity of propagation: 69.00%
– Propagation delay, max. 100MHz: 536 ns/100m
Usage characteristics
– Packaging: Reel in a box
– Length: 305 m
– Operating temperature, range: -20 to 60°C
– Ambient installation temperature, range: -10 to 50°C
– Minimum static operating bending radius: 32.0 mm
– Laying operation bending radius: 64.0 mm
– Category: Cat. 6
– Flame retardant: IEC 60332-1
– Fire ratardant: No
– Range: LANmark-6
– Field of application: Fix installations

CÔNG TY CỔ PHẦN GIẢI PHÁP MẠNG VIỄN THÔNG HỒNG QUANG chuyên phân phối cáp NexansCáp chống cháy NexansCáp mạng Nexans cho các đại lý và người dùng cuối. Nhà cung cấp Cáp mạng Nexans LANmark-6 Cat6 U/UTP chính hãng có CO/CQ cho các dự án, Cáp mạng Nexans LANmark-6 Cat6 U/UTP giá tốt nhất trên toàn quốc.